Sezibwa rooftop solar: panel layout and installer brief

For: the Green Volta installers and the NFE site team. Owner: Aaron Tushabe. Last reviewed: 21 Oct 2026. Status: proposed. The layout was worked out from satellite imagery, so do the site checks below before drilling.

The plan

Satellite layout: 8 panels on the NW roof face

Rails, clamps and string wiring drawing

Why this roof face

At 0.36° N the sun is close to overhead all year, so the direction a face points makes little difference:

Roof face kWh per year Worst month (kWh/day)
North-west (chosen) 6,780 16.8 (Nov)
South-west 6,770
South-east 6,660 15.7 (Jun)
North-east 6,640

PVGIS (SARAH3 data, 2005 to 2023), 20° pitch, 14% system losses, no tree shade.

The trees decide it. Tall trees stand against the north, north-east and east sides of the house, and big trees to the south and south-west. The north-west face looks away from most of them. All 8 panels are on one string, so shade on one panel pulls down all 8. The north-west face also gives the steadiest output through the year.

Site checks before drilling

Roof words used in the site checks

Words used in these checks

Word What it means How to check it on site
Ridge The top line of the roof, where the two roof faces meet.
Eave The bottom edge of the roof, where the gutter is.
Roof face One sloping side of the roof. Ours is the side facing the alley (north-west).
Pitch How steep the roof is, in degrees. Lay a phone level app on the sheet, pointing up the slope. Or use a 1 m level and the table in picture 4.
Face depth The distance from the eave to the ridge, measured along the sheet (following the slope, not on the ground). Run a tape up one rib from the gutter edge to the ridge. It must be at least 3.0 m.
Purlin Wooden strips under the iron sheets, running the same way as the ridge. The sheets are nailed to them, and the L-feet must screw into them. Each straight row of roofing nails across the roof is a purlin. Measure the gap between rows (picture 2).
Rafter The sloping timbers under the purlins, running from eave to ridge. Look inside the roof space if you can, and check for rot or termite damage.
Crest and valley The high ribs and the low channels of the corrugated sheet. Drill only through a crest. Rain runs down the valleys (picture 3).

Mounting

The hardware on the Muden quote matches this layout exactly: two 5.1 m rails per group of 4 portrait panels.

Item Per group Total On the quote
Rail, 5100 mm 2 4 4
End clamp 4 8 8
Inter clamp 6 12 12
L-foot 6 12 12

Wiring: one string of 8 into PV1

String of 8 SRNE ASP48120SH3, per PV input OK
Open-circuit voltage 422 V at 25 °C, about 440 V on a cold morning 800 V max ✓
Max-power voltage 359 V, about 310 V on a hot afternoon 200 to 650 V tracking range ✓
Current 13.4 A at max power, 14.0 A short-circuit 22 A max ✓
Power 4.8 kW 9 kW max ✓

The hot and cold figures assume typical n-type temperature coefficients (open-circuit voltage −0.27 %/°C, max-power voltage −0.30 %/°C), because the panel datasheet does not give them.

Not on the Muden quote: bring these

Commissioning

Expected output

Average kWh per day by month, unshaded, north-west face at 20° (PVGIS):

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
18.6 20.0 20.4 19.7 18.7 18.5 19.1 18.2 18.2 17.7 16.8 17.2

That is about 6,780 kWh a year. It agrees with the 5.2 peak-sun-hour assumption in the sizing re-run (about 19.5 kWh/day). Single days swing a lot with the weather. A month that comes in well below these figures points to shade or a wiring fault.