CalinMeter
We got the API docs here
User Manuals
- User instructions for the CA168-S Single-phase electricity meter (1).pdf
- CA168 Din Rail Meter- Technical Specification (1).pdf
- Installation Guide - Calin LoraWAN Smart Meters.pdf
β‘ CalinMeter Status Codes β Postpaid Quick Reference & Action Guide
π Common Meter Status / Short Codes (Postpaid Use)
Code |
Meaning |
Action |
---|---|---|
01 |
Cumulative total active kWh consumption |
Record/check usage trend |
14 |
Load threshold |
Compare with customer load, adjust if configured too low |
31 |
Current total active power |
Check load at moment of query |
35 |
Current total power factor |
If persistently low, investigate load/PF correction |
40 |
Number of meter cover open events |
Check tamper log; reseal if necessary |
41β45 |
Last 1stβ5th cover open times |
Verify tamper history |
46 |
Number of overload trip events |
Review load demand; advise upgrade if frequent |
47β51 |
Last 1stβ5th overload trip times |
Identify when overloads occurred |
52 |
Number of power down events |
Check supply reliability |
53β57 |
Last 1stβ5th power down times |
Cross-check with outage records |
58 |
Number of phase down events |
Investigate supply-side issues |
87 |
Reason for relay disconnecting |
Use table below for action |
π Code 87 β Relay Disconnect Reasons (Postpaid Mode)
Sub-Code |
Cause / Display |
Field Action |
---|---|---|
00 |
Relay Closed |
No issue, meter supplying load. |
1 |
No Credit |
(Ignore β prepaid only) |
3 |
Over Power |
Advise customer to reduce load; check load threshold config. |
4 |
Relay Test |
Normal test β no action needed. |
5 |
Open Upper Cover |
Reseal meter; enter clear tamper token. |
6 |
Open Terminal Cover |
Reseal meter; enter clear tamper token. |
7 |
Remote Disconnect |
Confirm if intentional (backend/HES). Reconnect if needed. |
8 |
Not-active |
Commission meter (default code: 12345). |
9 |
Over Current |
Inspect customer load for surges; advise mitigation. |
11 |
Over Voltage |
Report to utility; check feeder for high supply voltage. |
12 |
Under Voltage |
Report to utility; check feeder for low voltage. |
13 |
Current Reverse |
Inspect wiring/tamper; correct polarity. |
14 |
Open Enclosure Cover |
Reseal; enter clear tamper token. |
15 |
Magnetic Field Interference |
Investigate tamper with magnets; clear tamper token. |
16 |
Current Imbalance |
Check for phase/load imbalance. |
17 |
Neutral Line Interference |
Inspect neutral wiring/tamper. |
18 |
Bypass |
Inspect for illegal bypass; escalate if confirmed. |
21 |
Voltage Imbalance |
Investigate supply phase imbalance. |
22 |
Thermal Overload |
Inspect meter location (ventilation/overload). Allow cool-down. |
23 |
Low Power Factor |
Advise PF correction (capacitors). |
24 |
Tariff Error |
Backend config issue β escalate to admin. |
25 |
Remote Reconnect + Local Trip |
Local fault persists β troubleshoot cause (e.g., overload/tamper). |
β Quick Action Guide Summary