Recently Updated Pages
Optimal Solar and Battery Allocation (Sezibwa)
[!info] Conservative, bank-facing basis. Tariff: UEDCL Code 10.2 Q3 2026 (666.5 / 562.1 / 429.7,...
Battery Arbitrage Economic Case (Sezibwa)
[!info] Conservative basis: UEDCL Code 10.2 Q3 2026 tariff (666.5 / 562.1 / 429.7 UGX/kWh), real...
Solar Plus Battery Economic Case (Sezibwa)
[!info] Conservative, bank-facing basis (revised after two independent reviews) Tariff: UEDCL Co...
Battery Price Break-Even (Sezibwa)
[!info] Conservative basis. Tariff: UEDCL Code 10.2 Q3 2026 (666.5 / 562.1 / 429.7, configurable...
SRNE phase balancing: big consumers on one phase trip the inverter on battery
Problem When the site runs on battery (grid outage, typically evening or night), switching on a l...
SRNE TOU arbitrage: plan (#67)
The plan to turn on time-of-use battery arbitrage on the Sezibwa/Nansana SRNE inverter (logger i...
Inverter-monitor notifications: hardening + tuning (ADR-012)
How the NFE inverter-monitor decides what to alert on, and the 2026-08-10 hardening pass that ki...
SRNE ASP48120SH3 Safe Settings Write: design, registers, and commissioning (#53)
Purpose and scope This page documents the SRNE ASP48120SH3 safe settings write feature (story #53...
NFE metering strategy + Glen Street-EMS
Authoritative page for NFE's role in the IEEE Smart Village meshEMS / Street-EMS initiative. Com...
Metering protocols: DLMS/COSEM, OBIS, Modbus, MQTT (and NFE CHINT register map)
Traceable explainer: how metering data actually moves, where DLMS/COSEM, OBIS, Modbus, MQTT and ...